The binary format can be used to encode different data types, each with different fields. This document first describes the general format and then applies it to specific data types, including Trace Context and Tag Context.
Each encoding will have a 1 byte version followed by the version format encoding:
<version><version_format>
This will allow us to, in 1 deprecation cycle to completely switch to a new format if needed.
The version format for the version_id = 0 is based on ideas from proto encoding. The main requirements are to allow adding and removing fields in less than 1 deprecation cycle. It contains a list of fields:
<field><field>...
Each field is a 1-byte field ID paired with a field value, where the format of the field value is
determined by both the field ID and the data type. For example, field 0 in Trace Context
may
have a completely different format than field 0 in Tag Context
or field 1 in Trace Context
.
Each field that we send on the wire will have the following format:
<field_id><field_format>
field_id
is a single byte.
field_format
must be defined for each field separately.
The specification for a data type’s format must also specify whether each field is optional or
repeated. For example, Trace-id
in Trace Context
is optional, and Tag
in Tag Context
is repeated. The specification for a data type’s format MAY define a default value for any
optional field, which must be used when the field is missing.
The specification for a data type can define versions within a version of the format, called data type version, where each data type version adds new fields. The data type version can be useful for describing what fields an implementation supports, but it is not included in the serialized data.
Fields MUST be serialized in data type version order (i.e. all fields from version (i) of a data type must precede all fields from version (i+1)). That is because each field has its own format, and old implementations may not be able to determine where newer field values end. This ordering allows old decoders to ignore any new fields when they do not know the format for those fields. Fields within a data type version can be serialized in any order, and fields with the same field ID do not need to be serialized consecutively.
Because all the fields will be decoded in data type version order, the deserialization will simply read the encoded input until the end of the input or until the first unknown field_id. An unknown field id should not be considered a parse error. Implementations MAY pass on any fields that they cannot decode, when possible (by passing-through the whole opaque tail of bytes starting with the first field id that the current binary does not understand).
If we follow the rules that we always append the new ids at the end of the buffer we can add up to 127.
TODO(bdrutu): Decide what to do after 127: a) use varint encoding or b) just reserve 255 as a continuation byte.
We can stop sending any field at any moment and the decoders will be able to skip the missing ids and use the default values.
field_id
= 0len
= 16Is the ID of the whole trace forest. It is represented as an opaque 16-bytes array,
e.g. (in hex), 4bf92f3577b34da6a3ce929d000e4736
. All bytes 0 is considered invalid.
field_id
= 1len
= 8Is the ID of the caller span (parent). It is represented as an opaque 8-bytes array,
e.g. (in hex), 34f067aa0ba902b7
. All bytes 0 is considered invalid.
field_id
= 2len
= 1Controls tracing options such as sampling, trace level etc. It is a 1-byte representing a 8-bit unsigned integer. The least significant bit provides recommendation whether the request should be traced or not (1 recommends the request should be traced, 0 means the caller does not make a decision to trace and the decision might be deferred). The flags are recommendations given by the caller rather than strict rules to follow for 3 reasons:
The behavior of other bits is currently undefined.
{0, 0, 75, 249, 47, 53, 119, 179, 77, 166, 163, 206, 146, 157, 0, 14, 71, 54, 1, 52, 240, 103, 170, 11, 169, 2, 183, 2, 1}
This corresponds to:
traceId
= {75, 249, 47, 53, 119, 179, 77, 166, 163, 206, 146, 157, 0, 14, 71, 54}spanId
= {52, 240, 103, 170, 11, 169, 2, 183}traceOptions
= 1The Tag Context format uses Varint encoding, which is described in https://developers.google.com/protocol-buffers/docs/encoding#varints.
field_id
= 0field_format
= <tag_key_len><tag_key><tag_val_len><tag_val>
where
tag_key_len
is a varint encoded integer.tag_key
is tag_key_len
bytes comprising the tag key name.tag_val_len
is a varint encoded integer.tag_val
is tag_val_len
bytes comprising the tag value.